Back to List

Bare Die Data Sheet: 54ACT04


The 54ACT04 hex inverter gate contains six independent inverters performing the Boolean function Y = Ā. Internal circuitry comprises three stages with buffered output. Inputs are directly compatible with both standard TTL & CMOS outputs.
The device directly replaces legacy National / Fairchild 54ACT04, Motorola MC54ACT04, RCA HARRIS 54ACT04 and Texas Instruments SN54ACT04 or CD54ACT04.
Features:
** END OF LIFE ** NOT RECOMMENDED FOR NEW DESIGN
  • Outputs Sink/Source 24mA
  • Inputs directly accept TTL
  • Outputs Directly Interface to CMOS, NMOS, and TTL
  • Low Input Current: 1µA
  • Operating Voltage Range: 4.5 to 5.5V
  • Military temperature range
  • Direct drop-in replacement for obsolete components in long term programs
  • Function compatible with 54LS04
Vendor:
Silicon Supplies
  Electrical Datasheet

Die Physical Data:
Footprint: 1.885mm² (2921.759mil²)
X: 1300µm (51mil)
Y: 1450µm (57mil)
  Request Pad Layout

In Stock: Available on request
Product Families: Used for this device are tabulated below.
Functional:
  • I/P Level: CMOS/TTL
  • O/P Level: CMOS
  • Bits: 6
  • 3-State O/P: No
  • Schmitt Trigger: No
Specification:
VCC (Min): 4.50V
VCC (Max): 5.50V
fMIN @ VNOM: 90MHz
tpd (Max) @ VNOM: 9.3ns
ICC (Max) @ VNOM: 0.0800mA
VNOM (Max): 5.5V
Output Drive (Max): 24.0mA
Other Detail: Important information for this device is tabulated below.
Traffic light setting for Minimum Order Quantity indicates the following:
  • Green:Available from stock or at low factory MOQ.
  • Amber: Available on factory order with MOQ.
  • Red: High factory MOQ may apply, please ask for details.
Traffic light setting for High Reliability indicates the following:
  • Green: This bare die is specified and tested for use in high reliability applications.
  • Amber: This bare die can meet higher reliability specifications with additional testing & qualification, please ask for details.
  • Red: This bare die is not specified or specifically designed for use in high reliability applications.
Traffic light setting for Space Grade indicates the following:
  • Green: This bare die is qualified for space applications or has space level qualification data, please ask for details.
  • Amber: This bare die can be specified for space applications with additional testing and qualification, please ask for details.
  • Red: Suitability of this bare die for space applications is unknown and requires further qualification, please ask for details.