H Grade Screening Flow


Material is qualified to the H Grade flow in accordance with MIL-PRF-38534 Class H. The H Grade flow is used to provide quality assurance that outgoing material meets the DC electrical limits at the temperature extremities specified by the product datasheet. The sample distribution is wider than Class K with an assumption of homogeneity across a wafer batch.

H Screening Flow

Sample distribution - Single diffusion, Multiple Wafers

Sample size - 20 PCS (5 destruct)

Pre-Sample Assembly

Die Visual Inspection - MIL-STD-750/TM2072, MIL-STD-750/TM2071, MIL-STD-883/TM2010B

Sample Assembly

Die Attach - MIL-STD-883/TM2010

Die Shear Test - MIL-STD-883/TM2019

Die Attach Inspection - MIL-STD-883/TM2011

Wire bond – Internal spec 

Wire bond integrity - MIL-STD-883/TM2011

Pre-Cap inspection - MIL-STD-883/TM2010

Internal Die Visual - MIL-STD-883/TM2010B, MIL-STD-750/TM2072, MIL-STD-75/TM2073

Package seal - MIL-STD-883/TM1014

Seal Inspection - MIL-STD-883/TM2009

Sample coding – Internal spec

Sample Testing

Stability Bake - MIL-STD-883/TM1008

Interim Electrical Test @ 25°C - In accordance with device specification

Interim Electrical Test @ 125°C - In accordance with device specification

Interim Electrical Test @ -55°C - In accordance with device specification

120 hours burn-in @ 150°C - In accordance with device specification

Final Electrical Test @ 25°C - In accordance with device specification

Final Electrical Test @ 125°C - In accordance with device specification

Final Electrical Test @ -55°C - In accordance with device specification

Outgoing Die Release

From sample tested diffusion only

100% die visual inspection - MIL-STD-750/TM2072, MIL-STD-750/TM2071, MIL-STD-883/TM2010B